BOBCAT S130 – LIFT ARM BYPASS CONTROL VALVE – Testing

Raise the lift arms 6 feet (2 m) off the ground. Stop the engine. Turn the Lift Arm Bypass Control Knob (Item 1) [Figure 20-50-1] clockwise 1/4 turn. Then pull up and hold the Lift Arm Bypass Control Knob until the lift arms slowly lower.