BOBCAT S130 – BACK-UP ALARM SYSTEM – Adjusting Switch Position

NOTE: Joystick equipped machines do not have back-up alarm switches and can not be adjusted.

Standard Controls and ACS (If Equipped)

Stop the engine and raise the operator cab. (See Raising on Page 10-30-2.)

Place the steering levers in the neutral position.

Loosen the screws (Item 1) [Figure 60-210-3] securing the back-up alarm switches.

Position the back-up alarm switch rollers so that they just make contact with bellcranks without compressing the switch springs [Figure 60-210-3]. Torque the screws (Item 1) [Figure 60-210-3] securing the switches to the bracket to 14 – 19 in.-lb. (1,6 – 2,1 Nโ€ขm).

Lower the operator cab (See Lowering on Page 10-30-3.) and inspect back-up alarm system for proper function. (See Inspecting on Page 60-210-1.)