Use an approved recover / charging unit [Figure 70-40-5] to evacuate the system.
Connect the reclaimer to the excavator A/C charge ports.
IMPORTANT: Only A/C trained technicians should perform the reclaiming and recharging procedure.
Connect the Red hose (Item 1) [Figure 70-40-6] to the high pressure port and open the valve.
Connect the Blue hose (Item 2) [Figure 70-40-6] to the low pressure port and open the valve.
Turn the reclaimer unit to the ON position and follow the on screen instructions [Figure 70-40-7].
NOTE: For the correct quantity of refrigerant (See Capacities on Page SPECS-10-9)
NOTE: The reclaimer unit has a complete step by step set of instructions [Figure 70-40-8] to follow for reclamation and recharging of the A/C system. A trained technician should follow these instructions as they may vary slightly depending on the model and brand of reclaimer used.