BobCat E35 – DELUXE INSTRUMENT PANEL SETUP (S/N A93K11001 – A93K17999 AND AC2P11001 – AC2P14999) – Changing The Operator Password

Perform Password Entry at left, but do not start the engine.

Press and hold the ENTER CODE button (Item 1) for three seconds. CodE 1 will appear on the data display screen (Item 2) [Figure 50-90-1].

Press the ENTER CODE button until the desired Code (CodE 0, CodE 1, CodE 2, CodE 3) appears. CodE 0 is Owner Password, the other codes are Operator passwords.You now have 40 seconds to use the keypad (Item 3) [Figure 50-90-1] to enter each digit of a new four digit password.

Enter the new four digit password. After the fourth digit is entered, there will be two short beeps and rPEAt will appear.

Re-enter the new four digit password to verify. If the new passwords match, there will be two short beeps, Code will appear for 1 second and then the data display screen will return to HOURMETER function.

NOTE: If the new passwords do not match, there will be one long beep and Error will appear for 1 second and then the data display screen will return to HOURMETER function.