BobCat 753 – HYDRAULIC CONTROL VALVE (ADVANCED CONTROL SYSTEM) (ACS) – BICSTM Valve, Lift Arm By-Pass Orifice Removal and Installation

Remove the fitting (Item 1) [Figure 20-41-32] from the valve.

Using a flat blade screw driver, remove the lift arm by-pass orifice (Item 1) [Figure 20-41-33] & [Figure 20-41-34].

Orifice size is 0.078 inch.

Reverse the removal procedure to install the lift arm by-pass orifice.