Remove the fitting (Item 1) [Figure 20-41-32] from the valve.
Using a flat blade screw driver, remove the lift arm by-pass orifice (Item 1) [Figure 20-41-33] & [Figure 20-41-34].
Orifice size is 0.078 inch.
Reverse the removal procedure to install the lift arm by-pass orifice.