If it is necessary to use a booster battery to start the engine, BE CAREFUL! There must be one person in the
operator’s seat and one person to connect and disconnect the battery cables.
The key switch must be OFF (Standard Panel) OR the STOP Button must be pressed (Deluxe Panel). The booster battery must be 12 volt.
Connect the end of the first cable (Item 1) to the positive (+) terminal of the booster battery. Connect the other end
of the same cable (Item 2) [Figure 60-20-6] to the positive terminal on the loader starter.
Connect the end of the second cable (Item 3) to the negative (-) terminal of the booster battery. Connect the
other end of the same cable (Item 4) [Figure 60-20-6] to the engine.
Keep cables away from moving parts. Start the engine.
After the engine has started, remove the ground (-) cable (Item 4) [Figure 60-20-6] first.
Remove the cable from the positive terminal (Item 2) [Figure 60-20-6].