Remove the actuator from the hydraulic control valve.
(See Actuator Removal And Installation on Page 20-41-8.)
Check the mounting block (Item 1) [Figure 60-122-28] and bolts for wear and replace as needed.
Check the actuator wiring harness connector (Item 1)
[Figure 60-122-29] and replace if broken.
Installation: Install the wires into the connector as listed below. The terminal numbers are written on the back of the connector (Item 2) [Figure 60-122-29].
Lift and Tilt Actuator
1 – Terminal-Black/Green-Larger diameter wire (16 gauge)
2 – Terminal-Green-Larger diameter wire (16 gauge)
3 – Terminal-Red/Green-Larger diameter wire (16 gauge)
4 – Terminal-Open
5 – Terminal-Red-Smaller diameter wire (18 gauge)
6 – Terminal-Open
7 – Terminal-Open
8 – Terminal-Black-Smaller diameter wire (18 gauge)