BobCat S70 – HYDRAULIC CONTROL VALVE – Anti Cavitation/Check Valves Removal And Installation

Remove the Anti Cavitation/Check valve (Item 1) [Figure 20-40-34] from the tilt cylinder base end port.

Remove the O-rings (Item 1), and back-up washer (Item 2) [Figure 20-40-35] from the Anti Cavitation/Check valve.

Assembly: Always use new O-rings and back-up washer. Tighten to 35-40 ft.-lb. (47-54 Nโ€ขm) torque.

Remove the Anti Cavitation/Check valve (Item 1) [Figure 20-40-36] from the lift cylinder rod end port.

Remove the O-rings (Item 1), and back-up washer (Item 2) [Figure 20-40-37] from the Anti Cavitation/Check valve.

Assembly: Always use new O-rings and back-up washer. Tighten to 35-40 ft.-lb. (47-54 Nโ€ขm) torque.