BOBCAT S130 – HYDRAULIC CONTROL VALVE (ACS) OR (SJC) – Load Check Valve Removal And Installation (Tilt & Auxiliary)

At the front side of the control valve locate the tilt section load check valve (Item 1) [Figure 20-41-31].

At the front side of the control valve locate the auxiliary section load check valve (Item 2) [Figure 20-41-31].

NOTE: The tilt and auxiliary load check valves are interchangeable.

Remove the spring (Item 1) and poppet (Item 2) [Figure 20-41-32].

Check the orifice (Item 3) [Figure 20-41-32] in the poppet to be sure it is not plugged.

Installation: Install a new O-ring (Item 4) [Figure 20-41- 32] on the plug and lightly lubricate with oil before installing. Tighten the plug to 38 – 45 ft.-lb. (52 – 61 Nโ€ขm) torque.