BOBCAT S130 – HYDRAULIC CONTROL VALVE (ACS) OR (SJC) – Auxiliary Solenoid Removal And Installation

Remove the nut (Item 1) [Figure 20-41-85] from both solenoids.

Installation: Tighten the nut to 48 – 72 in.-lb. (5 – 8 Nโ€ขm) torque.

Remove the nut (Item 1) and solenoid coil (Item 2) [Figure 20-41-86].

Use an Ohm meter to measure the solenoid coil resistance.

The correct resistance for the coil is 4.9 ยฑ 0.25 ohm.

Remove the solenoid stem (Item 1) [Figure 20-41-87].

Installation: Tighten the stem to 10 – 14 ft.-lb. (14 – 19 Nโ€ขm) torque.

Remove the O-rings (Item 1) [Figure 20-41-88] from the solenoid stem.

Check and clean the screen (Item 2) [Figure 20-41-88].