BobCat 753 – REAR AUXILIARY DIVERTER VALVE (SINGLE SHUTTLE) – Disassembly

Clean the diverter block to remove dirt before disassembly. Block ports are labeled for correct assembly.

Remove the logic cartridge valves from block ports LC1 and LC2 (Item 1) [Figure 20-100-9].

Remove the pilot check valves from block ports PC1 and PC2 (Item 1) [Figure 20-100-10].

Remove the shuttle check valve from block port SH1 (Item 2) [Figure 20-100-10].

Remove the nuts (Item 1), seal washers (Item 2), and solenoid valve coils (Item 3) [Figure 20-100-11].

Remove the diverter control solenoid valve (Item 4) from port SV1. Remove the pressure relieving solenoid valve
(Item 5) [Figure 20-100-11] from block port SV2.