Posted on April 5, 2022 by Jack BobCat 753 – ALTERNATOR (90 AMP) – Rotor Ground Test Touch one probe to one of the slip rings and the other probe to the rotor shaft [Figure 60-31-21]. There should be no continuity. Replace the rotor if there is continuity.