The wire connector (Item 1) [Figure 60-123-8] can be removed from the handle sensor wires, use the following procedure.
Remove the wedge (Item 1) [Figure 60-123-9] from the connector.
With a pointed tool, lift the tab (Item 1) [Figure 60-123-10] and pull the wire from the connector.
Installation: Install the wires into the connector as listed below [Figure 60-123-10]:
1-Terminal – Red
2-Terminal – Black
3-Terminal – Green