If the charging system malfunctions check the following: Check the condition and tension of the alternator belt. (See Belt Adjustment on Page 60-30-1.) If belt…
Category: BOBCAT S130
Loosen the alternator mounting and adjustment bolts (Items 1 & 2) [Figure 60-30-1] and loosen the belt all the way. Remove the belt and install…
Stop the engine. Raise the operator cab. (See Raising on Page 10-30-2.) Loosen the alternator mounting bolt (Item 1) [Figure 60-30-1]. Loosen the adjustment bolt…
If it is necessary to use a booster battery to start the engine, BE CAREFUL! There must be one person in the operator’s seat and…
The battery cables must be clean and tight. Check the electrolyte level in the battery. Add distilled water as needed. Remove acid or corrosion from…
Open the rear door. Disconnect the negative (-) battery cable (Item 1) [Figure 60-20-1]. Remove the battery hold down clamp (Item 2) [Figure 60-20-1]. Disconnect…
Use a test meter to measure coil resistance [Figure 60-10-6]. Coil wires do not have polarity. Correct resistance for the pressure relief (small) coil is…
The electrical system is protected from overload by fuses and relays under the fuse panel cover (Item 1) [Figure 60-10-4]. A decal is inside the…
The following troubleshooting chart is provided for assistance in locating and correcting problems which are most common. Many of the recommended procedures must be done…
The loader has a 12 volt, negative ground alternator charging system. The electrical system is protected by a 100 amp master fuse (Item 1) [Figure…